##################################################################################################################################### # Data description for the manuscript "A test-retest reliability analysis of diffusion measures of white matter tracts relevant for # # cognitive control" by Boekel, Keuken and Forstmann. # # # # For any questions regarding the data please contact w.e.boekel@uva.nl or mckeuken@gmail.com # # # ##################################################################################################################################### ################## # Folder structure: ################## "subject number" "subject number" _ "scan type" _ "scan session" ################## # The MRI scans that are made available are: ################## - b0 (magnitude (de-faced) and phase) - t1 (de-faced) - dwi (4 runs per scan session) each run contains 34 volumes: volume 1: B0 Volume 2-33: the 32 directions Volume 34: the isotropic weighted average of the diffusion directions (phillips specific) ################## # The MRI scan parameters are: # (The scan parameters are taken from https://www.spinozacentre.nl/wiki/index.php/NeuroWiki:Sequences) ################## # b0: Scan technique 3D-FFE, multishot FFE Duration 108 seconds profile Linear turbo direction Z TE 3 ms TR 11 ms delta-TE 5 FA 8 Sense P (RL) 2.5 Sense S (FH) 2 slices 128 FOV 256x208x256 Voxel size 2^3 mm matrix 128 Foldover RL Fat shift P Water fat shift 1.13 Pixels Bandwidth 383 Hz TFE Factor 90 TFE shots 44 ################## # t1: Scan technique 3DFFE, multishot TFE Duration 3.06 minutes profile linear turbo direction Z TR 8.2 TE 3.8 FA 8 Sense P (RL) 2.5 Sense S (FH) 2 slices 220 FOV 240*188 Voxel size 1^3 mm matrix 240 Foldover RL Fat shift P Water fat shift 2,269 pixel Bandwidth 191.4 Hz TFE Factor 154 TFE shots 78 Shot interval 2375 slice orientation TRA NR of averages 2 ################## # dwi: Scan technique MS-SE, single shot DWI Duration 5.3 minutes TR 7542 TE 86 FA 90 SENSE (AP) 2 slices 60 FOV 224*224 Voxel size 2^3 mm Slice gap 0 matrix 112 Foldover AP Fat shift A Dyn Stab Yes Prepation Full Water fat shift 13.5 Bandwidth 32.1 EPI Factor 59 Fat supression SPIR frequency offset 250 gradient duration maximum NR of directions 32 b value 1000 gradient mode default ################## ################## # NOTES ################## Due to technical issues, for subject "pp06", we were unable to succesfulyl acquire the B0 image in the 2W session. Subject "pp20" - "pp34" were part of a new batch of subjects, in which the extra T1 measurements were dropped to optimize total scan duration since a single t1 image was sufficient for registration purposes. The t1 and b0 magnitude volumes per subject were "de-faced" using the "MRI_deface" tool as described in Bischoff-Grethe et al. (2007). A technique for the deidentification of structural brain MR images. Human Brain Mapping, 28(9): 892-903.